Medium frequency induction sintering furnace
Equipment composition
Medium frequency power supply KGPS-160KW-2.5KHz
Water-cooled furnace body
Note: The water-cooled furnace body is divided into inner and outer cylinders, which are made of a whole piece of steel plate. The inner cylinder body is made of stainless steel, and the outer cylinder material is Q235 . The head is made of standard head, the inner head is stainless steel, and the outer head is Q235 . The manufacturing methods and requirements are all in accordance with the provisions of GB150-89
Temperature control system and external operation cabinet .
Work platform (with stairs on both sides) .
Pre-vacuum system
The main technical indicators and functions
1. Working temperature: 2300 °C
2. Heating body material: tungsten
3. Heating body size Φ 370mm (inside diameter) h=700mm
4. Intermediate frequency power supply
(1 ) Power supply voltage: 380v; 50HZ; three-phase four-wire
(2 ) Maximum output power: 160KW
(3) Maximum output voltage: 750V
(4) Maximum operating frequency: 2500Hz
5. The temperature uses two independent temperature measurement systems consisting of Wre5-26 thermocouple and non-contact optical fiber sensing thermometer .
6. It adopts hydrogen protection, the flow rate is adjustable, and the hydrogen outlet is provided with slag discharge port .
security protection function
It has over-current, over-pressure, phase loss, and insufficient cooling water pressure protection.
With over temperature protection.
With power failure alarm function.
With hydrogen explosion-proof function.
water supply system
Water quality parameters.
Water pressure ≥ 0.2-0.4Mpa.
Effluent temperature < 55 °C
Inlet water temperature < 5-35 °C
Hardness CaO < 10mg equivalent
Acid-base ph = 7-8.5
Suspended solids < 10mg/L
Water resistance > 2.5K Ω
Iron containing < 2mg
2. Pool volume
Multiplied by the total power 4-0.05 take . If space is limited, when the small tank volume, can be added cooling towers. When the volume can be guaranteed, it is better to add a cooling tower to the south of the Yangtze River. North of the Yangtze River, may not be considered properly.
- Water lift
It should be 1.5 times the distance from the pool to the equipment .
- Water flow
Multiply the total power by 0.04 .